| Markenbezeichnung: | ITI -LINK |
| Modellnummer: | ITI-CT6F-027 |
| MOQ: | 1000 Stück |
| Preis: | 50$-100$ |
| Lieferzeit: | 15-45 Tage |
| Zahlungsbedingungen: | T/T |
| Construction Item Description | Electrical Property |
|---|---|
| Conductor Material: Bare Solid Copper (elongation: 19-24%) OD: 23 AWG |
Conductor Resistance at 20°C: ≤ 9.5 Ω / 100m Resistance unbalance within a pair: ≤ 2% |
| Insulation Material: HDPE OD: 1.15 ±0.01 mm Average THK: 0.25 mm Color: 1p: white + 2 blue stripes & blue, 2p: white + 2 orange stripes & orange, 3p: white + 2 green stripes & green, 4p: white + 2 brown stripes & brown |
Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V: >1500 MΩ / 100m Mutual capacitance: 5600 pF / 100m MAX Capacitance unbalance pair to ground at 800Hz or 1 kHz: ≤ 160 pF / 100m Characteristic impedance at 100MHz: 100 ± 15 Ω Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or 0.7 KV AC for 1 min: No breakdown |
| Pair Twist Lay & Direction: 1p: S=19.0 mm (27%), 2p: S=23.5 mm (35%), 3p: S=21.5 mm (31%), 4p: S=27.0 mm (40%) |
Mechanical Property Insulation elongation before aging: ≥ 300% Tensile strength before aging: ≥12 MPa Elongation after aging: ≥ 150 % Tensile strength after aging: ≥10.5 MPa |
| Inner Assemble Lay: S=90 ± 5 mm Direction: according to the drawing Filler: cross member 5.0X5.0X0.5mmT OD: / Filler: Ripcord: 300D Drain Wire: Tinned Copper |
Packing Drum: NA |
| Shield Construction: / Material: Polyester/Aluminium (PET/ALU) Coverage: ≥ 115% |
|
| Jacket Material: LSZH, 60P, -20~75℃ Hardness: 81± 3 OD: 7.2 ± 0.2 Average THK: 0.55 ~ 0.60 Color: Gray Marking Color: according to the customer's requirements Marking: according to the customer's requirements |
Jacket elongation before aging: ≥ 150 % Tensile strength before aging: ≥ 13.5 MPa Elongation after aging: ≥ 125 % Tensile strength after aging: ≥ 12.5 MPa |
| Property | Standard | Value |
|---|---|---|
| Conductor Resistance at 20°C | NF EN 50289-1-2 / IEC 60189-1 | ≤ 9.5 Ω / 100m |
| Resistance unbalance within a pair | NF EN 50289-1-2/ IEC 60708 | ≤ 5% |
| Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or 0.7 KV AC for 1 min | NF EN 50289-1-3 / IEC 61196-1-105 | No breakdown |
| Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V | NF EN 50289-1-4 / IEC 60885-1 | >1500 MΩ / 100m |
| Mutual capacitance | NF EN 50289-1-5 /IEC 60189-1 | 5600pF / 100m MAX |
| Capacitance unbalance pair to ground at 800Hz or 1 kHz | NF EN 50289-1-5 / IEC 60189-1 | ≤ 160 pF / 100m |
| Characteristic impedance at 100MHz | NF EN 50289-1-11/ IEC 61156-1 | 100 ± 15 Ω |
| Spark Test | UL444 | 2000 ± 250VOC |