logo
Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
SFTP CAT7 Cable
Created with Pixso. Wholesale Bulk CAT7 SFTP 23AWG PVC Purple Cable IEC60332-1 for Reliable Networks

Wholesale Bulk CAT7 SFTP 23AWG PVC Purple Cable IEC60332-1 for Reliable Networks

Brand Name: ITI -LINK
Model Number: ITI-CT7SF-013
MOQ: 1000pcs
Delivery Time: 15-45 Days
Payment Terms: T/T
Detail Information
Place of Origin:
Shenzhen
Certification:
UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
Cable Length:
1000 Ft
Shielding Type:
SFTP
Connector Type:
RJ45
Frequency:
600MHz
Conductor Size:
23 AWG
Color:
Purple
Jacket Material:
PVC
Cable Type:
CAT7
Packaging Details:
Wooden shaft packaging 40*26*20cm Outer box size:42*42*22cm
Supply Ability:
2000pcs/day
Product Description

Wholesale Bulk CAT7 SFTP 23AWG PVC Purple Cable IEC60332-1 for Reliable Networks

 

 

Product Description:

1. ITI-LINK ITI-CTF6A-013: Wholesale Bulk CAT7 SFTP 23AWG PVC Purple Cable IEC60332-1 – 1000FT for High-Speed & Reliable Networks

The ITI-LINK ITI-CTF6A-013 is a premium CAT7 SFTP PVC Purple Cable engineered for wholesale buyers and large-scale network deployments. With a 1000FT reel, 23AWG oxygen-free copper conductors, and SFTP (Shielded Foiled Twisted Pair) double shielding, this cable delivers 600MHz bandwidth and 10Gbps data transfer. Compliant with IEC60332-1 fire safety standards, its purple PVC jacket ensures durability, easy identification, and reliable performance in high-density network environments. Ideal for bulk orders, it combines EMI resistance, safety, and visual organization for mission-critical networks.
 

2. 23AWG Copper & SFTP Shielding: Uncompromised Performance in High-Speed Networks

Featuring 23AWG oxygen-free copper conductors and SFTP double shielding, the ITI-CTF6A-013 CAT7 SFTP PVC Cable offers:

 

  • Ultra-Low Signal Loss: 23AWG gauge minimizes attenuation over 100 meters, supporting stable 10Gbps transmission at 600MHz—essential for data centers handling 5,000+ concurrent connections.
  • 99.9% EMI/RFI Blockage: SFTP’s dual-layer shielding (aluminum foil + braided shield) eliminates interference from industrial machinery, power lines, and adjacent network cables, ensuring zero data corruption.
  • Backward Compatibility: Seamlessly integrates with legacy Ethernet systems, providing flexibility for network upgrades in enterprise campuses and smart buildings.
     

3. Purple PVC Jacket & IEC60332-1 Compliance: Safety Meets Visual Efficiency

The purple PVC jacket and IEC60332-1 certification of the ITI-CTF6A-013 provide key advantages:

 

  • Fire Safety Assurance: Meets IEC60332-1 fire resistance requirements, reducing smoke and toxic gas emissions in case of fire—critical for data centers, financial institutions, and government facilities.
  • Visual Network Management: The distinctive purple color reduces patch panel errors by 60% in complex network setups, enabling color-coded identification of high-priority cables.
  • Environmental Durability: PVC insulation resists moisture, abrasion, and moderate heat, extending the cable’s lifespan in indoor conduit systems and industrial environments.
    The 1000FT reel format optimizes logistics for bulk orders, covering 100+ server racks per reel and minimizing installation waste.
     

4. Bulk-Ready Features for Efficient Network Deployments

Designed for wholesale buyers, the ITI-CTF6A-013 includes:

 

  • Volume Discounts: Enjoy up to 35% savings on orders exceeding 200 reels, ideal for system integrators and large enterprises.
  • Logistics Optimization: 1000FT reels fit standard shipping pallets, reducing freight costs by 40% compared to smaller lengths.
  • Factory Testing: Every batch undergoes 100% verification for 600MHz bandwidth, NEXT, and return loss, ensuring consistent performance across all cables.
  • Custom Solutions: Branded labeling, custom lengths, and staggered deliveries available to meet specific project requirements.

 

5. Conclusion: The Premier CAT7 SFTP PVC Cable for Bulk Networks

The ITI-LINK ITI-CTF6A-013 combines high-speed performance, robust shielding, and wholesale efficiency. Whether wiring a 10,000-node data center or a city-wide smart network, its 23AWG conductors, purple PVC jacket, and IEC60332-1 compliance ensure reliable, secure connectivity. Backed by a 5-year warranty and dedicated bulk sales support, it’s the go-to choice for professionals seeking scalable, high-performance networking solutions.

 

 

 

Technical Parameters:

Product Attribute Description
Cable Type Cat7 Ethernet Cable
Shielding Type SFTP Cat7 Cable
Conductor Material Copper
Conductor Size 23AWG
Jacket Material PVC
Jacket Color Purple
Frequency 600MHz
Length 1000Ft

 

 

Product Description:Wholesale Bulk CAT7 SFTP 23AWG PVC Purple Cable IEC60332-1 for Reliable Networks
Rev.: A ECN Description:
Construction Item Description Electrical Property

 

Conductor

 

Material

Bare Solid Copper(elongation:

19-24%)

Conductor Resistance at 20°C ≤ 9.5 Ω / 100m
OD 23 AWG Resistance unbalance within a pair ≤ 2%

 

 

 

 

 

Insulation

Material PE Skin-Foam-Skin Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

 

>1500 MΩ / 100m

OD 1.33 ±0.01 mm Mutual capacitance 5600 pF / 100m MAX
Average THK 0.37mm Capacitance unbalance pair to ground at 800Hz or 1 kHz ≤ 160 pF / 100m

 

 

Color

1p: white + 2 blue stripes & blue Characteristic impedance at 100MHz 100 ± 15 Ω

2p: white + 2 orange stripes &

orange

Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or

0.7 KV AC for 1 min

 

No breakdown

3p: white + 2 green stripes & green Mechanical Property
4p: white + 2 brown stripes & brown

 

 

insulation

elongation before aging ≥ 300%

 

 

Pair Twist

 

 

Lay & Direction

1p: S=19.0 mm (28%) tensile strength before aging ≥16 MPa
2p: S=23.5 mm (31%) elongation after aging ≥ 150 %
3p: S=21.5 mm (33%) tensile strength after aging ≥10.5 MPa
4p: S=25.0 mm (36%)

 

 

jacket

elongation before aging ≥ 150 %
OD / tensile strength before aging ≥ 13.5 MPa

 

Inner Assemble

Lay S=90 ± 5 mm elongation after aging ≥ 125 %
Direction according to the drawing tensile strength after aging ≥ 12.5 MPa
OD / Packing

 

Filler

Ripcord 3*250D Drum NA
Drain Wire /    

 

 

Pair Shield

Shield Pair Shield

 

 

 

 

 

Construction /
Material Polyester/Aluminium (PET/ALU)
Coverage ≥ 115%

 

Braid

Material ɸ 0.12mm Aluminum-magnesium braided
Coverage ≥ 40%

 

 

 

 

Jacket

Material PVC, 60P, -20~75℃
Hardness 81± 3
OD 8.1 ± 0.2
Average THK 0.55 ~ 0.65

 

Color

according to the customer's requirements
Marking Color black
Marking

according to the customer's

requirements

 

 

Transmission Properties
CAT7 ANSI/TIA-568.2-D; IEC 61156-6; YD/T1019-2013

 

 

No.

 

Frequency

 

Attenuation (Max)

Propagation Delay

(Max)

Propagation Delay Skew

(Max)

 

Return Loss (Min)

 

NEXT (Min)

 

PS NEXT (Min)

 

EL-FEXT (Min)

 

PS EL-FEXT (Min)

MHz dB/100m ns/100m ns/100m dB(on 100m) dB(on 100m) dB(on 100m) dB(on 100m) dB(on 100m)
1 4 3.74 552 25 23.00 78.0 75.30 78.0 75.00
2 8 5.24 547 25 24.50 78.0 75.0 75.90 72.90
3 10 5.86 545 25 25.00 78.0 75.0 74.00 71.00
4 16 7.41 543 25 25.00 78.0 75.0 69.90 66.90
5 20 8.29 542 25 25.00 78.0 75.0 68.00 65.00
6 25 9.29 541 25 24.30 78.0 75.0 66.00 63.00
7 31.25 10.41 540 25 23.60 78.0 75.0 64.10 61.10
8 62.5 14.88 539 25 21.50 75.50 72.40 55.10 55.10
9 100 19.20 538 25 20.10 72.40 69.40 54.00 51.00
10 150 23.56 537 25 18.90 69.80 66.80 50.20 47.20
11 200 27.74 536 25 18.00 67.80 64.90 48.00 45.00
12 250 30.97 536 25 17.30 66.40 63.40 46.00 43.00
13 300 34.19 536 25 17.30 65.20 62.20 44.50 41.50
14 600 50.10 536 25 17.30 60.70 57.70 38.40 35.40
15 800 58.92 535 25 17.30 58.90 55.90 35.90 32.90
16 1000 66.93 535 25 17.10 57.40 54.40 34.00 31.00

 

 

Electrical Properties
Conductor Resistance at 20°C NF EN 50289-1-2 / IEC 60189-1 ≤ 9.5 Ω / 100m
Resistance unbalance within a pair NF EN 50289-1-2/ IEC 60708 ≤ 2%

Dielectric Strength

Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min

 

NF EN 50289-1-3 / IEC 61196-1-105

 

No breakdown

Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

 

NF EN 50289-1-4 / IEC 60885-1

>1500 MΩ / 100m
Mutual capacitance NF EN 50289-1-5 /IEC 60189-1 5600pF / 100m MAX
Capacitance unbalance pair to ground at 800Hz or 1 kHz NF EN 50289-1-5 / IEC 60189-1 ≤ 160 pF / 100m
Characteristic impedance at 100MHz NF EN 50289-1-11/ IEC 61156-1 100 ± 15 Ω
Spark Test UL444 2000 ± 250VOC

 

Applications:

Target Applications: High-Speed & Reliable Networks
Data Centers & Cloud Facilities
As horizontal cabling in data centers, the ITI-CTF6A-013 CAT7 SFTP PVC Cable enables:

10Gbps connectivity across 500+ server racks, supporting cloud computing, big data analytics, and virtualization.
Purple color coding streamlines cable management in high-density racks, reducing maintenance time by 50%.


Enterprise Campuses & Smart Buildings
For large-scale office networks, the cable:

Handles bandwidth-intensive applications like 4K video conferencing, IoT deployments, and unified communications.
IEC60332-1 compliance ensures safety in multi-story buildings with strict fire regulations.
 

Financial Trading Hubs
In high-frequency trading environments, this cable ensures:

Sub-millisecond latency for real-time data transmission, with SFTP shielding protecting against electromagnetic interference.
Bulk orders support standardized cabling across trading floors with 1,000+ terminals.

 

Wholesale Bulk CAT7 SFTP 23AWG PVC Purple Cable IEC60332-1 for  Reliable Networks 0
 

FAQ:

Q: What is the brand name of this product?

A: The brand name of this product is ITI-LINK.

 

Q: What is the model number of this product?

A: The model number of this product is ITI-CT7SF-013.

 

Q: Where is this product manufactured?

A: This product is manufactured in SHENZHEN.

 

Q: What is the maximum data transfer rate of this cable?

A: This cable is a CAT7 cable and has a maximum data transfer rate of 10Gbps.

 

Q: Is this cable suitable for outdoor use?

A: No, this cable is not suitable for outdoor use.

 

Q: How are Cat7 shielded network cables grounded?
A: Generally, single ended grounding is adopted: one end of the shielded wire is grounded and the other end is suspended.